JINGCHENG Water Heating Hose is an electrically heated constant-temperature hose for heated water and aqueous solution transfer lines, heat resistant up to 100°C, with higher temperatures on request. This buyer FAQ answers the questions process engineers ask most often about the JINGCHENG Water Heating Hose, using the 100°C rating and the seven-size catalog table, from bore and pressure to voltage, sensor and what to send for a quotation.
Buyers who specify a constant temperature water heating hose for the first time usually ask the same questions: what the hose is for, how hot it can run, which size to choose, which voltage and sensor to order, and what to send for a quotation. This FAQ answers those questions with the figures published in the JINGCHENG 2025 Electrically Heated Hose Catalog for the Water Heating Hose, listed under constant temperature hoses.
The catalog rates the hose at heat resistance up to 100°C, with higher temperatures available on request, and states that every line can be customized to your requirements. The seven-size standard table covers 1/4" to 1" inner diameter.
It is an electrically heated hose for heated water and aqueous solution transfer lines that must hold a set temperature between two connection points. An unheated water line loses heat to the room, so the temperature at the outlet drifts and, in cold areas, the line can cool far below the process set point. The JINGCHENG hose heats and insulates at the same time. The heating layer is made of uniformly braided heating elements, which minimize temperature differences along the inner wall, and the hose is built with high-efficiency insulation selected with the surface temperature in mind.
The standard catalog rating is 100°C. If the process needs a higher temperature, say so in the enquiry; a higher rating is available on request and must be confirmed before the hose is built. Do not set the controller above the rating marked on the hose.
Seven standard inner diameters from 1/4" to 1" are listed, with ID and OD tolerance of ±0.2 mm on the outer diameter column:
Inner Diameter (inch) | Outer Diameter (mm ±0.2) | Working Pressure (bar) | Working Pressure (psi) | Burst Pressure (bar) | Burst Pressure (psi) | Min. Bend Radius (mm) |
|---|---|---|---|---|---|---|
1/4" | 9 | 173 | 2501 | 690 | 10005 | 30 |
5/16" | 11 | 158 | 2284 | 630 | 9137 | 40 |
3/8" | 12.4 | 135 | 1958 | 540 | 7830 | 60 |
1/2" | 15.9 | 118 | 1704 | 470 | 6815 | 150 |
5/8" | 19 | 88 | 1269 | 350 | 5075 | 180 |
3/4" | 22.6 | 85 | 1234 | 340 | 4930 | 260 |
1" | 29.5 | 75 | 1088 | 300 | 4350 | 300 |
Data source: JINGCHENG 2025 Electrically Heated Hose Catalog. Heat resistance up to 100°C; higher temperature on request. Confirm the rating at your operating temperature with our engineers when ordering.
Working pressure falls as the bore grows, from 173 bar (2501 psi) at 1/4" to 75 bar (1088 psi) at 1". Burst pressure is four times working pressure on each row. The 5/16" burst pressure is 630 bar (9137 psi); the psi figure printed for this row in the catalog is a typographical error and is replaced here by 630 bar × 14.5 and is not an operating value. Always size the line so that the highest system pressure stays below the working pressure for that bore.
Start from the required flow and the space available for bends:
1/4", 5/16" and 3/8" have minimum bend radii of 30 mm, 40 mm and 60 mm, so they can follow equipment frames closely. Their working pressures are the highest in the table.
From 1/2" upward the minimum bend radius jumps to 150 mm and reaches 300 mm at 1". These bores move more water with less pressure drop, but they need more room at every turn and at the hose reel or rack.
Check the outer diameter as well (9 mm to 29.5 mm) when you select clamps, guides and wall pass-throughs. If you are unsure, send the flow, the route length and a simple sketch and our engineers will suggest a size.
Every hose is built to the controller it will be wired to. Catalog options are:
Rated voltage: 380 Vac, 220 Vac, 110 Vac, 12 Vdc or other
Temperature sensor: Type J or Type K thermocouple, Ni120, PT100, PT1000 or other
Rated power: 110, 150, 170 or 200 W/m, or other
Length: 3 m, 4.5 m, 5 m, 6 m, 10 m or other
End fittings: US, British or metric thread at each end, or other
Match the sensor type to the input of the existing temperature controller. A mismatch is a common cause of unstable readings.
The catalog operating environment used for these heated hoses is ambient -40°C to +55°C, relative humidity not above 85%, and atmospheric pressure 86 kPa to 106 kPa. The surrounding air should not contain gases that corrode metal or damage insulation. For unusual environments, ask us to confirm a custom construction.
The catalog prohibits twisting the hose about its own axis and warns that a bend tighter than the table radius can damage the hose. Connect one end first, let the hose find its natural lay, hold the fitting with a second spanner while tightening, and support the hose so it does not hang from its fittings. Leave a short straight section at each end before the first bend. These points are covered in more detail in our installation and routing notes; they are the items buyers most often ask about before placing an order.
Medium (water or the aqueous solution) and the set temperature
Maximum temperature (100°C standard; higher on request)
Working pressure, including peaks
Bore from the table above, or a custom size
Length and any tight bends in the route
Voltage, power, sensor type and pin layout
Fitting standard and size at each end
With this information JINGCHENG can confirm the right constant temperature water heating hose and send a quotation quickly.