JINGCHENG Gas Sampling Hose is an electrically heated, bend and kink resistant sample line for flue gas pretreatment equipment, online monitoring equipment, infrared and ultraviolet sampling analyzers and laboratory test equipment, heat resistant up to 230°C. This page shows how to survey an existing sample path, choose one of the three catalog bores, remove cold spots at fittings, define the electrical interface and commission the upgraded heated sample line.
Many gas analysis systems start life with a short or unheated sample line, then grow: the probe moves to a new sampling point, a pretreatment unit is added, an analyzer is replaced, or the monitoring task changes. A line that was adequate before can now be too long, too cold or routed through places it was never meant to go. Typical symptoms are moisture in the sample path, readings that drift or respond slowly, blocked fittings and recurring kinks. Retrofitting a heated sample hose is often the most direct way to remove those symptoms without redesigning the whole system. This guide explains how to plan that upgrade.
JINGCHENG's gas sampling hose is an electrically heated sample line for flue gas pretreatment equipment, online monitoring equipment, infrared and ultraviolet sampling analyzers and laboratory test equipment. It is bend and kink resistant with stable heat retention, and heat resistant up to 230°C (higher on request). Uniformly braided heating elements keep the inner-wall temperature difference small, so there is no cold section where condensate can form, and high-efficiency insulation is selected with the outer surface temperature in mind.
Before choosing a replacement, record what is installed now:
Route and length from the sampling probe to the pretreatment unit, conditioner or analyzer inlet, including every platform crossing, cable tray and cabinet entry.
Bore of the existing tubing and of the fittings at each end.
Thread standard at each end — US, British or metric — and whether adapters are already in the line.
Temperature requirement of the analysis method and the dew point of the gas; this sets the line temperature the new hose must hold.
Available power and control: supply voltage, spare controller channels and the sensor type the controller can read.
Problem history: where condensate collected, where kinks or blockages occurred, and how often.
The catalog page for this hose lists three small-bore sizes selected for sample-gas flow: 3/16", 1/4" and 5/16". Outer diameters are 7.6, 9 and 11 mm (±0.2), working pressure is 203 bar (2936 psi), 173 bar (2501 psi) and 158 bar (2284 psi), burst pressure is four times working pressure, and minimum bend radius is 30 mm for 3/16" and 1/4" and 40 mm for 5/16".
Inner Diameter (inch) | Outer Diameter (mm ±0.2) | Working Pressure (bar) | Working Pressure (psi) | Burst Pressure (bar) | Burst Pressure (psi) | Min. Bend Radius (mm) |
|---|---|---|---|---|---|---|
3/16" | 7.6 | 203 | 2936 | 810 | 11745 | 30 |
1/4" | 9 | 173 | 2501 | 690 | 10005 | 30 |
5/16" | 11 | 158 | 2284 | 630 | 9137 | 40 |
Data source: JINGCHENG 2025 Electrically Heated Hose Catalog. Heat resistance up to 230°C; higher temperature on request. Confirm the rating at your operating temperature with our engineers when ordering.
For a retrofit, match the new bore to the sample flow and to the existing fittings where possible; a size change at each end adds adapters, dead volume and potential cold spots.
The goal of a retrofit is a sample path that stays above the dew point from the probe to the conditioner. When planning the heated hose:
Run the heated section continuously across the length where condensation occurred, instead of bridging only part of the route.
Keep fittings and transitions short. Every unheated adapter or union is a place where condensate can start.
Plan the route within the bend radius. The hose is bend and kink resistant, but bends next to fittings and cabinet entries should still stay at or above the listed radius.
Avoid lateral twist. Twisting the hose sideways during or after installation can cause leakage, flow loss, hose damage or fire.
Supply voltage: 380 Vac, 220 Vac, 110 Vac, 12 Vdc or other, according to the power available at the sampling point or analyzer shelter.
Rated power: 110, 150, 170 or 200 W/m, or another value matched to the required line temperature and ambient conditions.
Sensor: Type J or Type K thermocouple, Ni120, PT100 or PT1000 — the type your existing controller channel reads, so the retrofit can use the installed control hardware.
Pin layout: specify the connector pin assignment at each end; the hose is wired according to the pin table supplied with it.
The catalog operating conditions are an ambient temperature of -40°C to +55°C, relative humidity not above 85%, atmospheric pressure 86–106 kPa and supply voltage 12–380 Vac. Stack platforms and outdoor sampling points often see the extremes of that range. The surrounding atmosphere should not contain gases that corrode metal or damage insulation, conductive media or heavy mold; for special environments, ask for a custom build.
Confirm that the controller reads a plausible ambient temperature from the new sensor before heating.
Heat the line to its set point and let it settle before sample gas is drawn.
Check both fittings for leaks once the line is at temperature.
Compare analyzer response with the problem history recorded in Step 1, and keep the new set point and observations on file.
Replacing an unheated or partly heated line between a flue gas probe and a pretreatment unit.
Extending the sample path after an analyzer or conditioner has been relocated.
Upgrading the heated inlet of an infrared or ultraviolet sampling analyzer.
Adding a flexible heated line to laboratory benches, test rigs or portable flue gas sampling setups.
Every JINGCHENG electrically heated hose is built to order. Send the survey data from Step 1 — gas, required line temperature, bore, length, voltage, sensor type, thread standard and pin layout at each end. A model code such as JCH-200-16-B-3X220-P2-8 (working temperature, bore, inner-tube type, supply, sensor, working pressure) can summarize the result. JINGCHENG engineers will propose a matching heated sample line specification and quotation.