| Availability: | |
|---|---|
| Quantity: | |
Soren20061126
JINGCHENG
3917290000 3904610000 3917390000
JINGCHENG Medical Hose is an electrically heated hose for all types of medical equipment, built with a custom medical-grade inner tube for the conveyed medium and heat resistant up to 230°C, with every line available as a custom build. This size and temperature guide uses the catalog table of seven sizes from 1/4" to 1" ID rated 173 bar down to 75 bar, with minimum bend radii from 30 mm to 300 mm, so the bore and heat rating can be confirmed for the device fluid line.
JINGCHENG Medical Hose (医药用管) is an electrically heated hose for all types of medical equipment. The 2025 Electrically Heated Hose Catalog describes a custom medical-grade inner tube for the conveyed medium, and states that every line can be built to the required specification. The catalog rates the hose heat resistant up to 230°C (higher on request). The hose both heats and insulates: the heating layer is made of uniformly braided heating elements, which minimize the temperature difference along the inner wall, and the hose is built with high insulation-efficiency materials selected with the surface temperature in mind.
This size and temperature guide uses the seven catalog sizes and the 230°C heat-resistance rating so the bore, bend radius and temperature can be confirmed for an OEM device fluid line before the hose is ordered. This page follows the catalog wording only and does not add claims that are not printed there.
Inner Diameter (inch) | Outer Diameter (mm ±0.2) | Working Pressure (bar) | Working Pressure (psi) | Burst Pressure (bar) | Burst Pressure (psi) | Min. Bend Radius (mm) |
|---|---|---|---|---|---|---|
1/4" | 9 | 173 | 2501 | 690 | 10005 | 30 |
5/16" | 11 | 158 | 2284 | 630 | 9137 | 40 |
3/8" | 12.4 | 135 | 1958 | 540 | 7830 | 60 |
1/2" | 15.9 | 118 | 1704 | 470 | 6815 | 150 |
5/8" | 19 | 88 | 1269 | 350 | 5075 | 180 |
3/4" | 22.6 | 85 | 1234 | 340 | 4930 | 260 |
1" | 29.5 | 75 | 1088 | 300 | 4350 | 300 |
Data source: JINGCHENG 2025 Electrically Heated Hose Catalog. Heat resistance up to 230°C; higher temperature on request. Confirm the rating at your operating temperature with our engineers when ordering.
The standard table lists seven inner diameters from 1/4" to 1":
1/4" — 9 mm OD, 173 bar (2501 psi) working, 690 bar (10005 psi) burst, 30 mm minimum bend radius.
5/16" — 11 mm OD, 158 bar (2284 psi) working, 630 bar (9137 psi) burst, 40 mm bend radius.
3/8" — 12.4 mm OD, 135 bar (1958 psi) working, 540 bar (7830 psi) burst, 60 mm bend radius.
1/2" — 15.9 mm OD, 118 bar (1704 psi) working, 470 bar (6815 psi) burst, 150 mm bend radius.
5/8" — 19 mm OD, 88 bar (1269 psi) working, 350 bar (5075 psi) burst, 180 mm bend radius.
3/4" — 22.6 mm OD, 85 bar (1234 psi) working, 340 bar (4930 psi) burst, 260 mm bend radius.
1" — 29.5 mm OD, 75 bar (1088 psi) working, 300 bar (4350 psi) burst, 300 mm bend radius.
Burst pressure is four times working pressure on each row and is a design margin, not an operating or test target. Outer diameter tolerance is ±0.2 mm. All seven sizes share a 4:1 ratio between burst and working pressure. The larger bores carry more fluid per minute, while the smaller bores are lighter and can be routed more tightly inside a compact enclosure.
The catalog rating is heat resistance up to 230°C. If the process needs a higher temperature, JINGCHENG can build a custom hose; state the required temperature in the enquiry and our engineers will confirm the design. The catalog table does not publish a separate pressure-derating curve against temperature, so this page does not invent one. Confirm the rating at your operating temperature when ordering.
The catalog operating environment is ambient -40°C to +55°C with relative humidity not above 85%, atmospheric pressure 86–106 kPa and supply voltage 12–380 Vac. Insulation keeps heat in the line, and the braided heating layer keeps the bore temperature even from end to end. The surrounding medium must not contain gases that corrode metal or damage insulation, or conductive media; for special environments a customized hose is available.
Choose a rated power of 110, 150, 170 or 200 W/m, or another value matched to the fluid and the enclosure conditions, so the line reaches working temperature without over-driving the heater.
The inner tube is described in the catalog as a custom medical-grade inner tube for the conveyed medium. All lines can be customized as required. Specify the fluid, the target temperature and any inner-tube preference in the enquiry; this page does not attach further material or document claims beyond that catalog statement.
Start from the pump or module output and the length of the fluid path inside the device. A long line or a higher flow usually benefits from a larger bore. A short line in a tight enclosure often works best with 1/4", 5/16" or 3/8", whose minimum bend radii are 30 mm, 40 mm and 60 mm.
Confirm that the working pressure of the chosen row is above the system pressure.
Check every planned turn at the hose centreline against the catalog minimum for that size. The sharp step at 1/2" (150 mm) is easy to miss when a line is upgraded from 3/8". Leave a short straight section next to each end connection. Do not force the hose.
Check the outer diameter against glands, clips, panels and enclosure openings.
Avoid lateral twist when routing or servicing the hose. Twisting the hose sideways can cause leakage, flow loss, hose damage or fire.
Catalog lengths are 3 m, 4.5 m, 5 m, 6 m, 10 m or other. If you are unsure of the size, send the flow, pressure, temperature and the tightest bend on the layout and our engineers will suggest a bore.
A complete enquiry usually states the fluid, the working and maximum pressure, the required hose temperature, the inner diameter from the table, the length, the fittings at each end (US, British or metric), the electrical supply (380 Vac, 220 Vac, 110 Vac, 12 Vdc or other), the sensor type (Type J or Type K thermocouple, Ni120, PT100 or PT1000), the rated power and the pin layout. A model code such as JCH-200-16-B-3X220-P2-8 summarizes the core data in one line. Inner-tube options are B (stainless steel corrugated tube), TB (PTFE hose with stainless steel braid), T (PTFE hose) and X (special material).
The hose is used on medical equipment fluid lines that must be held at a controlled temperature. Send the device layout, fluid, temperature, route and fitting details, and our engineers will confirm the medical equipment heated hose build.