JINGCHENG Special Equipment Connection Hose is an electrically heated high-pressure hose with a Daikin PTFE inner tube, 304 stainless steel pressure wire and uniformly braided heating elements, heat resistant up to 230°C and buildable up to 40 MPa or higher on custom order. This page follows the hose from unpacking to the first production shift: checking the delivered hose against the order, routing without twist or tight bends, wiring to the pin table, and a controlled first heat-up and pressure-up.
A special-equipment heated hose is usually specified with care: bore, pressure, temperature, sensor and fittings are all agreed before the order. Many early failures, however, are not caused by the specification at all. They start on the day the hose is fitted to the machine — a twisted run between the pump and the dispensing head, a loop pulled tighter than its bend radius next to a fitting, a connector wired to the wrong pins, or a first heat-up carried out before anyone has confirmed that the sensor reading is real. This guide follows the hose from unpacking to the first production shift so that the performance listed in the catalog table is what the equipment actually gets.
JINGCHENG's special-equipment connection hose is an electrically heated high-pressure hose for domestic and imported special machinery that moves hot, viscous media such as resins, fats and oils. The inner tube is Daikin PTFE (Teflon), the pressure layer is 304 stainless steel pressure wire, the heating layer is made of uniformly braided heating elements, and high-efficiency insulation is chosen with the outer surface temperature in mind. Heat resistance is up to 230°C (higher on request), and working pressure can be built up to 40 MPa or higher as a custom design.
Before the hose goes near the machine, compare it with the confirmed specification:
Inner diameter and length — the bore must match the row you sized from (5/16" to 1-1/2" in the standard table) and the length must cover the route without tension.
Supply voltage and power — 380 Vac, 220 Vac, 110 Vac, 12 Vdc or a custom value, with the agreed watts per meter (110, 150, 170 or 200 W/m, or other).
Sensor type — Type J or Type K thermocouple, Ni120, PT100 or PT1000. The controller must be set to read the same type.
Thread standard at each end — US, British or metric — and the connector pin layout at the host end and the head end.
Model code — a code such as JCH-200-16-B-3X220-P2-8 records working temperature (200°C), bore (Φ16 mm), inner-tube type, supply (3X220), sensor (PT100 two-wire) and working pressure (8 MPa). It is the fastest way to confirm that the hose in the box is the hose that was ordered.
The catalog table for this hose lists eight standard sizes. Working pressure falls as the bore grows, from 113 bar (1631 psi) at 5/16" to 50 bar (725 psi) at 1-1/2", and the minimum bend radius grows from 15 mm to 200 mm. Before installation, write the working pressure and bend radius of your row on the installation sheet; both numbers are used in the steps below.
Inner Diameter (inch) | Outer Diameter (mm ±0.2) | Working Pressure (bar) | Working Pressure (psi) | Burst Pressure (bar) | Burst Pressure (psi) | Min. Bend Radius (mm) |
|---|---|---|---|---|---|---|
5/16" | 13.3 | 113 | 1631 | 450 | 6525 | 15 |
3/8" | 15.5 | 110 | 1595 | 440 | 6380 | 20 |
1/2" | 19 | 88 | 1269 | 350 | 5075 | 25 |
5/8" | 22.7 | 70 | 1015 | 280 | 4060 | 30 |
3/4" | 27 | 65 | 943 | 260 | 3770 | 60 |
1" | 34 | 57.5 | 834 | 230 | 3335 | 85 |
1-1/4" | 43 | 52.5 | 761 | 210 | 3045 | 155 |
1-1/2" | 49.5 | 50 | 725 | 200 | 2900 | 200 |
Data source: JINGCHENG 2025 Electrically Heated Hose Catalog. Heat resistance up to 230°C; higher temperature and pressure available as custom builds. Confirm the rating at your operating temperature with our engineers when ordering.
No lateral twist. The hose must not be twisted sideways during or after installation. Twisting can cause leakage, flow loss, hose damage or fire. Lay the hose out naturally, connect one end, then let the hose find its position before connecting the second end.
Respect the bend radius. Keep every bend at or above the radius for your size — for example 25 mm at 1/2", 60 mm at 3/4" and 155 mm at 1-1/4". Bends that are too tight can damage the hose and cause short circuit, leakage or fire. The area directly behind each fitting is where tight bends most often occur.
Allow for movement. If the hose serves a moving head or a vibrating frame, check the route at both end positions of the stroke.
Keep the environment within limits. The catalog operating conditions are an ambient temperature of -40°C to +55°C, relative humidity not above 85%, atmospheric pressure 86 kPa to 106 kPa and supply voltage in the 12 Vac to 380 Vac range. The surrounding atmosphere should not contain gases that corrode metal or damage insulation, conductive media or heavy mold; special environments call for a custom build.
Wire the hose strictly according to its technical data and the pin table supplied with it. The pin table lists the function of every pin at the host end and at the head end; heater, sensor and any earth connections must land on the matching terminals of the equipment. If the hose is replacing an older line, do not assume the old pin assignment is the same — check it against the new table.
A careful first start protects both the hose and the process:
Verify the sensor reading at ambient temperature before switching on heating power. A reading that is far from room temperature points to a wrong sensor type setting or a wiring error.
Heat the empty or static line to the set point and watch the controller. The temperature should rise steadily and settle; erratic readings mean the wiring or controller settings should be checked before going further.
Introduce the medium only after the hose has reached temperature, so viscous fluid does not enter a cold bore and thicken.
Bring pressure up gradually and inspect both fittings for leakage. Stay within the working pressure of your row — burst pressure, about four times working pressure in this table, is a safety margin and not an operating target.
Record the commissioning values — set point, settled reading, pressure and route — so later inspections have a reference.
The catalog recommends that the hose is handled only by authorized and trained personnel, ideally the same dedicated operators. Unauthorized modification or adjustment of the hose voids the warranty. If a situation arises that the instructions do not cover, contact JINGCHENG so that our engineers can guide the installation.
Typical installations are hot-fluid connections on special machinery (pumps, melters, tanks and dispensing heads), viscous media lines that must not solidify or thicken, insulated hot-fluid transfer between process units, and custom replacement hoses built to the original parameters of domestic and imported special equipment.
Send the medium, set temperature, continuous and peak pressure, bore, length, supply voltage, sensor type, thread standard and pin layout at each end. JINGCHENG engineers will propose a matching specification and quotation, and every hose is checked for defects before it is packed and shipped.