| Availability: | |
|---|---|
| Quantity: | |
Soren20060804
JINGCHENG
3917290000 3904610000 3917390000
Waterproofing construction equipment must operate reliably in environments that are far less controlled than a factory production line.
On roofs, bridges, tunnels and outdoor construction sites, the hose may be exposed to wind, low ambient temperatures, dust, moisture, dragging and repeated movement.
At the same time, it must transfer viscous waterproofing material at a stable temperature.
A weather-ready heated hose for non-curing waterproofing equipment is designed to maintain material flow while supporting operation in demanding outdoor environments.
The temperature of a waterproofing material may be correct inside the machine but fall rapidly as it enters a long transfer hose.
This problem becomes more serious when:
Ambient temperature is low
Wind removes heat from the hose surface
The hose is installed outdoors
Material flow stops temporarily
The hose length is relatively long
The coating has high viscosity
The application point is far from the pump
If the material cools, the system may experience:
Increased viscosity
Reduced spray output
Higher pump pressure
Irregular spray patterns
Material buildup
Partial blockage
Longer startup time
Interrupted construction
Active heating and thermal insulation help compensate for these conditions.
The product is intended for waterproofing construction equipment, particularly systems transferring non-curing coating materials.
These materials often require controlled temperature to remain pumpable and sprayable.
The hose acts as a temperature-maintained connection between:
Heating tank
Material pump
Mixing or metering section
Spray machine
Application gun
The catalog states that Jingcheng has cooperated with leading companies in the waterproofing-equipment industry since 2013.
The product is described as offering stable performance and durability in harsh weather and demanding construction environments.
This long-term application background is relevant because waterproofing hoses must withstand both process requirements and job-site conditions.
The hose uses uniformly arranged heating elements to reduce temperature variation along the inner wall.
This can help maintain:
Stable coating viscosity
More consistent spray output
Lower blockage risk
Reduced pump-load fluctuation
Faster restart after short pauses
More predictable construction performance
The insulation layer reduces heat loss while helping control the external surface temperature.
The final outer structure should be selected according to the expected construction environment.
Possible considerations include:
Abrasion from dragging
Dust exposure
Moisture
Material splash
Sunlight
Low ambient temperature
Repeated bending
Contact with rough surfaces
Specific waterproof, weatherproof or ingress-protection requirements must be confirmed separately. The general product name alone should not be treated as a formal IP rating.
The standard product supports temperatures up to:
230°C
The actual temperature should be determined according to the waterproofing material, viscosity, hose length and pump system.
Inner Diameter | Outer Diameter | Working Pressure | Burst Pressure | Minimum Bending Radius |
|---|---|---|---|---|
1/2" | 15.9 mm | 118 bar / 1,704 psi | 470 bar / 6,815 psi | 150 mm |
5/8" | 19 mm | 88 bar / 1,269 psi | 350 bar / 5,075 psi | 180 mm |
3/4" | 22.6 mm | 85 bar / 1,234 psi | 340 bar / 4,930 psi | 260 mm |
Final operating pressure depends on material temperature, fittings, hose length and complete assembly design.
Non-curing waterproof coating equipment
Roof waterproofing machines
Bridge-deck waterproofing systems
Tunnel construction equipment
Basement waterproofing machinery
Heated bituminous coating transfer
Spray-applied waterproofing systems
Viscous construction-material conveying
Mobile waterproofing equipment
Outdoor coating machinery
Replacement spray-hose assemblies
Please provide:
Waterproofing material
Required operating temperature
Material viscosity
Normal working pressure
Maximum pump pressure
Required flow rate
Hose length
Inner diameter
Voltage
Heating power
Temperature sensor
Machine-side fitting
Spray-gun fitting
Electrical connector
Equipment model
Outdoor protection requirements
Original hose or drawing
