| Availability: | |
|---|---|
| Quantity: | |
Soren20061117
JINGCHENG
3917290000 3904610000 3917390000
JINGCHENG Medical Hose is an electrically heated hose for all types of medical equipment, built with a custom medical-grade inner tube for the conveyed medium and heat resistant up to 230°C. This page walks a device designer through six integration steps — route, bore, fluid connections, electrical interface, environment and series specification — ending with a one-page checklist.
Choosing the right heated hose is only half of the work for a medical equipment designer. The hose then has to be integrated into the device: routed through a compact enclosure, connected to the fluid path, wired to the controller and protected from strain over the life of the product. Integration decisions made early in the design save rework at the prototype stage and make series production repeatable. This guide walks through those decisions for the JINGCHENG medical hose.
JINGCHENG's medical hose is suitable for all types of medical equipment. It uses a custom medical-grade inner tube for the conveyed medium, and every line can be customized to requirements.
Heating and insulation in one component. The heating layer is made of uniformly braided heating elements that minimize the temperature difference along the inner wall, so the medium sees an even temperature along the line.
Insulation chosen for surface temperature. High insulation-efficiency materials are used with the hose surface temperature in mind — important when the line runs close to other parts inside an enclosure.
Temperature headroom. Heat resistance up to 230°C, with higher temperatures available on request.
Inner tube matched to the medium. The inner tube is customized for the medium the device conveys; define the medium early so that the tube can be specified correctly.
Draw the route before choosing a length. Note every bend, the space available around it and any moving parts nearby. The minimum bend radius from the catalog table is the key constraint: from 30 mm for 1/4" up to 300 mm for 1". Leave a little slack so that the hose is never pulled tight against its fittings, and never route it with a lateral twist — twisting can cause leakage, flow loss, hose damage or fire.
Inner Diameter (inch) | Outer Diameter (mm ±0.2) | Working Pressure (bar) | Working Pressure (psi) | Burst Pressure (bar) | Burst Pressure (psi) | Min. Bend Radius (mm) |
|---|---|---|---|---|---|---|
1/4" | 9 | 173 | 2501 | 690 | 10005 | 30 |
5/16" | 11 | 158 | 2284 | 630 | 9137 | 40 |
3/8" | 12.4 | 135 | 1958 | 540 | 7830 | 60 |
1/2" | 15.9 | 118 | 1704 | 470 | 6815 | 150 |
5/8" | 19 | 88 | 1269 | 350 | 5075 | 180 |
3/4" | 22.6 | 85 | 1234 | 340 | 4930 | 260 |
1" | 29.5 | 75 | 1088 | 300 | 4350 | 300 |
Data source: JINGCHENG 2025 Electrically Heated Hose Catalog. Heat resistance up to 230°C; higher temperature on request. Confirm the rating at your operating temperature with our engineers when ordering.
Compact devices usually favor the small bores, which bend tightly and keep the volume of medium held in the line low. Larger bores reduce flow resistance on longer runs but need more space for bends. Size the bore from the flow the device needs and the route you drew in Step 1.
The catalog offers US, British or metric threads at each end, or other fittings on request. Specify each end separately, because the source side and the delivery side of a device often use different connection standards. Keep the area right behind each fitting free of sharp bends.
Supply voltage: 380 Vac, 220 Vac, 110 Vac, 12 Vdc or other — choose the one available inside the device.
Rated power: 110, 150, 170 or 200 W/m, or other, matched to the set point and to the heat loss of the route.
Sensor: Type J or Type K thermocouple, Ni120, PT100, PT1000 or other, matched to the controller input on the device board or temperature module.
Pin table: define pin number, wire color and function at the controller end so that the hose plugs straight into the device harness.
The catalog operating window is ambient -40°C to +55°C, relative humidity not above 85% and atmospheric pressure 86 kPa to 106 kPa. The surroundings must not contain gases that corrode metal or damage insulation, or conductive media, and severe mold must not be present. If the device will be used outside this window, ask for a customized hose.
Once a prototype hose is proven, record its full specification in a model code such as JCH-200-16-B-3X220-P2-8:
200 — working temperature in °C
16 — inner diameter in mm
B — inner tube type (B = stainless steel corrugated tube, TB = PTFE hose with stainless steel braid, T = PTFE hose, X = special material)
3X220 — supply voltage
P2 — sensor type (P2 = PT100 two-wire, P3 = PT100 three-wire, K or J thermocouple, W = no sensor, T = special sensor)
8 — working pressure in MPa
Together with the drawing of fittings, length and pin table, this code lets every production batch be built to the same specification.
Route drawn with all bends at or above the minimum bend radius
Bore chosen from the catalog table for flow and space
Medium defined for the custom inner tube
Fittings specified separately for each end
Voltage, power and sensor matched to the device electronics
Pin table agreed with the device harness
Operating environment confirmed
Final specification recorded as a model code
Only authorized, trained personnel should install or service the hose; unauthorized modification or adjustment voids the warranty. Wire every hose according to its technical data and the supplied pin table, and contact JINGCHENG engineers when a situation arises that the instructions do not cover.
Send your device type, conveyed medium and temperature, route sketch, preferred bore and length, supply voltage, sensor type, fitting standards and pin layout. JINGCHENG engineers will confirm a medical hose specification and quotation for prototypes and series supply; every hose is checked for defects before packing and shipment.